Adding port speed in port_config.ini for the platforms AG9032 and Quanta IX1B#2923
Adding port speed in port_config.ini for the platforms AG9032 and Quanta IX1B#2923Prasanth-KV wants to merge 3 commits intosonic-net:masterfrom
Conversation
…i during first boot. Since speed is missing in port_config.ini, config_db does not have the speed and port-channel speed calculation fails. Solution: speed is been added in port_config.ini of the platforms - AS5712, AS7712, AS7816, AS7326, AG9032 and Quanta IX4
|
Could you change the name of the commit? Better to state what's changed in this commit. |
Changed the name of the commit. |
|
Can someone please help in triggering build again for Broadcom and VS platforms? The failure is due name resolution failure. distutils.errors.DistutilsError: Download error for https://files.pythonhosted.org/packages/38/d8/3789eb77845f8700bd12943835fdbd79b693c2f009cdcb985d7d33884f6c/setuptools_scm-3.3.3-py3.5.egg#sha256=38c714af0f04999f12c419b39bdae9969ebe94af40b230b0999afb5004a8deab: [Errno -3] Temporary failure in name resolution |
|
Hi all, |
|
@Prasanth-KV |
…i during first boot. Since speed is missing in port_config.ini, config_db does not have the speed and port-channel speed calculation fails. Solution: speed is been added in port_config.ini of the platforms - AS5712, AS7712, AS7816, AS7326, AG9032 and Quanta IX4
roylee123
left a comment
There was a problem hiding this comment.
It's OK for accton device, AS5712, AS7712, AS7816 and AS7326.
But no guarantee to AG9032 and Quanta IX1B.
|
Thanks @roylee123 |
device/accton/x86_64-accton_as7712_32x-r0/Accton-AS7712-32X/port_config.ini
Outdated
Show resolved
Hide resolved
device/accton/x86_64-accton_as5712_54x-r0/Accton-AS5712-54X/port_config.ini
Outdated
Show resolved
Hide resolved
|
retest vsimage please |
|
I do not see much progress. @Prasanth-KV, can you split the PR for accton, so that we can merge? |
#3213 contains these changes for Accton platforms and it is already merged. I will remove those files from this PR. We can merge this PR if Delta and Quanta port_config.ini gets reviewed. |
… taked in PR#3213
- What I did
Made sure that the default port speed is been populated in config_db during first initialization for the hardware platforms, AS5712, AS7712, AS7816, AS7326, AG9032 and Quanta IX1B.
- How I did it
Speed is been added in port_config.ini of the platforms - AS5712, AS7712, AS7816, AS7326, AG9032 and Quanta IX1B
- How to verify it
- Description for the changelog
Speed is been added in port_config.ini of the platforms - AS5712, AS7712, AS7816, AS7326, AG9032 and Quanta IX1B
- A picture of a cute animal (not mandatory but encouraged)