Current Behavior
The FC takes a single VBAT reading on startup which is reported in the OSD, telemetry & Blackbox logs for the duration of the flight. When the LED strip is disabled battery monitoring functions normally.
Steps to Reproduce
On the Kakute H7 target
- Voltage Meter Type set to ADC.
- Enable RGB LED strip.
Expected behavior
It would be nice to have battery monitoring and the blinking lights too.
Suggested solution(s)
I've applied the same fix made to the Matek H7 target in #7816 to a local copy of 4.1 and it "appears" to work fine.
- FC Board name and vendor: Holybro Kakute H7
- INAV version string: INAV/KAKUTEH7 4.1.0