Warm reboot: How the FlexCounter was handled after init view? #862
Description
Description
With the buffer pool in config db, then do warm reboot, the syncd can't handle the FlexCounter with new VID, in "processFlexCounterEvent".
Even after apply view, the syncd should not be able to get the counter for this new VID.
Steps to reproduce the issue:
- the config db has the buffer_pool.
- do warm reboot
- check syslog
config db:
"BUFFER_POOL": { "egress_pool": { "mode": "dynamic", "size": "100000", "type": "egress" } },
Describe the results you received:
syslog after warmboot:
Jul 15 07:40:46.978278 sonic ERR syncd#syncd: :- translateVidToRid: unable to get RID for VID oid:0x18000000000647
Jul 15 07:40:46.978385 sonic WARNING syncd#syncd: :- processFlexCounterEvent: port VID oid:0x18000000000647, was not found (probably port was removed/splitted) and will remove from counters now
Jul 15 07:40:46.978474 sonic NOTICE syncd#syncd: :- removeBufferPool: Trying to remove nonexisting buffer pool 0x18000000000647 from flex counter BUFFER_POOL_WATERMARK_STAT_COUNTER
Describe the results you expected:
Error free warmboot, and buffer pool counter should be collected correctly by Flexcounter after warmboot.
Additional information you deem important (e.g. issue happens only occasionally):
Attach sai rec
sairedis.rec.zip
The buffer pool VID before warm reboot is 0x180000000005cd.
After warm reboot, in init view, the buffer pool VID is 0x18000000000647, the orchagent attach the flex counter to the new VID, but syncd failed because no RID yet.
Even after apply view, the syncd should not be able to get the counter for this new VID 0x180000000005cd.
Because the processFlexCounterEvent will not be called for this new VID after apply view.