What I did:
Make sure Everflow always gets classified as Mirror table and not as Control Plane on multi-asic platforms.

Why I did:
In Multi-asic platforms we generate Everflow acl table data from minigraph for both host and namespace.
It is possible in multi-asic minigraph if there are no external port-channel (Only Router Port IP Interface) then Everflow table will have no binded interface in host and will gets classified as Control Plane ACL while in namespace gets classified as Mirror Table.
For ACL Rule generation we read global db as source of truth for acl table information and so for everflow rule generation if tables gets classified as Control plane we can generate rules with invalid action causing orchagent to throw runtime error.

How I did:
If the table is attach to erspan interface in minigraph then it always gets classified as mirror table.

How I verify:

Added unit-test case where minigraph only have External Router Port IP interface and no external port-channels.

abdosi added 4 commits April 3, 2021 01:41
df46ed418e661a9bccdb2639d8873def356f8ba0 (HEAD -> master, origin/master, origin/HEAD) Fix the LLDP_LOC_CHASSIS not getting populated if no remote neighbors are present (sonic-net#39)
e487532e11cc0e97cfce573b6b997fdd0beeb660 [CI] Set up CI&PR with Azure Pipelines (sonic-net#38)
3c9f488490a1dbded20dbf2d8a88a5ab4dbda8df Replace swsssdk's SonicV2Connector with swsscommon's implementation (sonic-net#35)

Signed-off-by: Abhishek Dosi <[email protected]>
Added sample minigraph for multi-asic platforms that does not have
external port-channels and only have Router Port IP Interface.

Signed-off-by: Abhishek Dosi <[email protected]>
Copy link
Contributor

@arlakshm arlakshm left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

lgtm

@abdosi abdosi merged commit 8ec3bdc into sonic-net:master Apr 7, 2021
@abdosi abdosi deleted the acl_binding branch April 7, 2021 20:35
abdosi added a commit that referenced this pull request Apr 7, 2021
…or table (#7241)

Make sure Everflow always gets classified as Mirror table and not as Control Plane on multi-asic platforms.

Why I did:
In Multi-asic platforms we generate Everflow acl table data from minigraph for both host and namespace.
It is possible in multi-asic minigraph if there are no external port-channel (Only Router Port IP Interface) then Everflow table will have no binded interface in host and will gets classified as Control Plane ACL while in namespace gets classified as Mirror Table.
For ACL Rule generation we read global db as source of truth for acl table information and so for everflow rule generation if tables gets classified as Control plane we can generate rules with invalid action causing orchagent to throw runtime error.

How I did:
If the table is attach to erspan interface in minigraph then it always gets classified as mirror table.
raphaelt-nvidia pushed a commit to raphaelt-nvidia/sonic-buildimage that referenced this pull request May 23, 2021
…or table (sonic-net#7241)

Make sure Everflow always gets classified as Mirror table and not as Control Plane on multi-asic platforms.

Why I did:
In Multi-asic platforms we generate Everflow acl table data from minigraph for both host and namespace.
It is possible in multi-asic minigraph if there are no external port-channel (Only Router Port IP Interface) then Everflow table will have no binded interface in host and will gets classified as Control Plane ACL while in namespace gets classified as Mirror Table.
For ACL Rule generation we read global db as source of truth for acl table information and so for everflow rule generation if tables gets classified as Control plane we can generate rules with invalid action causing orchagent to throw runtime error.

How I did:
If the table is attach to erspan interface in minigraph then it always gets classified as mirror table.
qiluo-msft pushed a commit that referenced this pull request May 24, 2021
…or table (#7241)

Make sure Everflow always gets classified as Mirror table and not as Control Plane on multi-asic platforms.

Why I did:
In Multi-asic platforms we generate Everflow acl table data from minigraph for both host and namespace.
It is possible in multi-asic minigraph if there are no external port-channel (Only Router Port IP Interface) then Everflow table will have no binded interface in host and will gets classified as Control Plane ACL while in namespace gets classified as Mirror Table.
For ACL Rule generation we read global db as source of truth for acl table information and so for everflow rule generation if tables gets classified as Control plane we can generate rules with invalid action causing orchagent to throw runtime error.

How I did:
If the table is attach to erspan interface in minigraph then it always gets classified as mirror table.
carl-nokia pushed a commit to carl-nokia/sonic-buildimage that referenced this pull request Aug 7, 2021
…or table (sonic-net#7241)

Make sure Everflow always gets classified as Mirror table and not as Control Plane on multi-asic platforms.

Why I did:
In Multi-asic platforms we generate Everflow acl table data from minigraph for both host and namespace.
It is possible in multi-asic minigraph if there are no external port-channel (Only Router Port IP Interface) then Everflow table will have no binded interface in host and will gets classified as Control Plane ACL while in namespace gets classified as Mirror Table.
For ACL Rule generation we read global db as source of truth for acl table information and so for everflow rule generation if tables gets classified as Control plane we can generate rules with invalid action causing orchagent to throw runtime error.

How I did:
If the table is attach to erspan interface in minigraph then it always gets classified as mirror table.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Projects

None yet

Development

Successfully merging this pull request may close these issues.

3 participants