[platform-celestica]: Add new fancontrol service for haliburton device#2736
Conversation
|
Can you please post the results and as well the command to run the tests? |
|
For fan speed control validation test, thermal test ambient range from 20C–45C–20C to complete 1 cycle, 5C each step, waiting the temperature reach stable state and change to next step, record all fan speed data from Result: Fan speed curve based on FSC algorithm (F2B) Result: Fan speed curve based on FSC algorithm (B2F) Conclution: The actual fan speed curve match fan speed control algorithm setting and all components temperature is under the required operating conditions. |
|
Is there a automated way to test this script ? Reason: We would like to test this locally, when we get the updated image |
|
@renukamanavalan , In this version we didn't prepare the way for automate test, |
…lly (#14942) src/sonic-swss * f977724 - (HEAD -> 202205, origin/202205) [bugfix] vnet ping missing with secondary endpoints empty in priority routes. (#2736) (2 hours ago) [siqbal1986] * a723a99 - Fix orchagent missing request when logrotate happens. (#2712) (2 hours ago) [mint570] * 24db6da - Handle duplicate routes in a graceful manner (#2688) (2 hours ago) [prabhataravind]
… routes. (sonic-net#2736) Adding a priority vnet route without secondary endpoints with custom monitoring does not result in vnet ping session creation. This change fixes that and adds a test. Signed-off-by: siqbal1486 <[email protected]>


- What I did
- How I did it
- How to verify it
Signed-off-by: Wirut Getbamrung [email protected]