Skip to content

Add new HWSKU Arista-7060X6-16PE-384C-O128S2-FANOUT so that we can get back to back Paladin ports up with Arista-7060X6-16PE-384C-O128S2#22508

Merged
StormLiangMS merged 3 commits intosonic-net:masterfrom
kewei-arista:pr-master-moby.1
May 21, 2025
Merged

Add new HWSKU Arista-7060X6-16PE-384C-O128S2-FANOUT so that we can get back to back Paladin ports up with Arista-7060X6-16PE-384C-O128S2#22508
StormLiangMS merged 3 commits intosonic-net:masterfrom
kewei-arista:pr-master-moby.1

Conversation

@kewei-arista
Copy link
Contributor

Why I did it

Currently when we loaded HWSKU Arista-7060X6-16PE-384C-O128S2 on two moby devices and connect their Paladin ports back to back, we can't get link up. It may help if we can get these links up and run the tests.

Work item tracking
  • Microsoft ADO (number only):

How I did it

Created a new FANOUT HWSKU containing special lanemap and polarity configs so that we can load Arista-7060X6-16PE-384C-O128S2 on one Moby and Arista-7060X6-16PE-384C-O128S2-FANOUT and get Paladin ports up when connecting them back to back with the following setup:

Moby1                                    Moby2
HWSKU: Arista-7060X6-16PE-384C-O128S2    HWSKU: Arista-7060X6-16PE-384C-O128S2-FANOUT
#17                 <->                  #18
#19                 <->                  #20
#21                 <->                  #22
#23                 <->                  #24

#18                 <->                  #17
#20                 <->                  #19
#22                 <->                  #21
#24                 <->                  #23

How to verify it

Verified that all the Paladin ports can link up with the above setup.

Which release branch to backport (provide reason below if selected)

  • 201811
  • 201911
  • 202006
  • 202012
  • 202106
  • 202111
  • 202205
  • 202211
  • 202305
  • msft-202412

Tested branch (Please provide the tested image version)

  • msft-202412

Description for the changelog

Created Arista-7060X6-16PE-384C-O128S2-FANOUT based on Arista-7060X6-16PE-384C-O128S2 and only update lanemap and polarity settings in bcm config.

Link to config_db schema for YANG module changes

A picture of a cute animal (not mandatory but encouraged)

…t back to back Paladin ports up with Arista-7060X6-16PE-384C-O128S2.
@mssonicbld
Copy link
Collaborator

/azp run Azure.sonic-buildimage

@azure-pipelines
Copy link

Azure Pipelines successfully started running 1 pipeline(s).

@mssonicbld
Copy link
Collaborator

/azp run Azure.sonic-buildimage

@azure-pipelines
Copy link

Azure Pipelines successfully started running 1 pipeline(s).

@mssonicbld
Copy link
Collaborator

/azp run Azure.sonic-buildimage

@azure-pipelines
Copy link

Azure Pipelines successfully started running 1 pipeline(s).

@liushilongbuaa
Copy link
Contributor

/azpw ms_conflict

1 similar comment
@r12f
Copy link
Contributor

r12f commented May 15, 2025

/azpw ms_conflict

Copy link
Contributor

@StormLiangMS StormLiangMS left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

LGTM

@mssonicbld
Copy link
Collaborator

Cherry-pick PR to msft-202412: Azure/sonic-buildimage-msft#1144

@mssonicbld
Copy link
Collaborator

Cherry-pick PR to 202505: #22719

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Projects

None yet

Development

Successfully merging this pull request may close these issues.

6 participants