Skip to content

[202311][Mellanox] Enable CMIS host management (#16846)#17684

Merged
yxieca merged 1 commit intosonic-net:202311from
Junchao-Mellanox:202311_cp_16846
Jan 5, 2024
Merged

[202311][Mellanox] Enable CMIS host management (#16846)#17684
yxieca merged 1 commit intosonic-net:202311from
Junchao-Mellanox:202311_cp_16846

Conversation

@Junchao-Mellanox
Copy link
Copy Markdown
Collaborator

Cherry-pick PR #16846

  • Why I did it Enable CMIS host management for Mellanox devices which are expected to support the feature

  • How I did it new thread in a new file and changing logic in platform code in chassis.py which is calling this thread from get_change_event() this thread in the new file handles the state machine per port. first the static detection takes place once the thread is up (during switch bootup sequence), until final decision if it's FW control or SW control module. After it ends, the dynamic detection takes place, listening to changes in the sysfs fds, per port, so it will be able to detect plug in or out events of a cable.

  • How to verify it Enhanced unit tests
    run sonic mgmt on Nvidia SN4700 with CMIS host management enabled

Why I did it

Work item tracking
  • Microsoft ADO (number only):

How I did it

How to verify it

Which release branch to backport (provide reason below if selected)

  • 201811
  • 201911
  • 202006
  • 202012
  • 202106
  • 202111
  • 202205
  • 202211
  • 202305

Tested branch (Please provide the tested image version)

Description for the changelog

Link to config_db schema for YANG module changes

A picture of a cute animal (not mandatory but encouraged)

- Why I did it
Enable CMIS host management for Mellanox devices which are expected to support the feature

- How I did it
new thread in a new file and changing logic in platform code in chassis.py which is calling this thread from get_change_event()
this thread in the new file handles the state machine per port.
first the static detection takes place once the thread is up (during switch bootup sequence), until final decision if it's FW control or SW control module.
After it ends, the dynamic detection takes place, listening to changes in the sysfs fds, per port,
so it will be able to detect plug in or out events of a cable.

- How to verify it
Enhanced unit tests
run sonic mgmt on Nvidia SN4700 with CMIS host management enabled
@yxieca yxieca merged commit 7368df7 into sonic-net:202311 Jan 5, 2024
@Junchao-Mellanox Junchao-Mellanox deleted the 202311_cp_16846 branch January 8, 2024 01:50
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

3 participants