Notifications
You must be signed in to change notification settings - Fork 1.8k
Description
Description
In VOQ chassis, in the linecard syslog, series of following error logs are seen for all asic instances. These errors are seen during the linecard boot up
ERR swss0#orchagent: :- doTask: Failed to get port object for port id 0x10000000000a9
ERR swss0#orchagent: :- doTask: Failed to get port object for port id 0x10000000000ac
ERR swss0#orchagent: :- doTask: Failed to get port object for port id 0x1000000000130
.
.
.
ERR swss1#orchagent: :- doTask: Failed to get port object for port id 0x101000000000118
ERR swss1#orchagent: :- doTask: Failed to get port object for port id 0x101000000000105
ERR swss1#orchagent: :- doTask: Failed to get port object for port id 0x101000000000115
.
.
.
Steps to reproduce the issue:
- Have a VOQ chassis with a supervisor card and a linecard (single asic or multiple asic)
- Reboot chassis with appropriate minimum configuration like switch_type = "voq"
- Check the syslog. For all asics instances of the linecard the above error will be seen dring initialization time.
Describe the results you received:
As given in the description section above
Describe the results you expected:
The reported errors should not be seen.
Output of show version:
N/A
Output of show techsupport:
N/A
Additional information you deem important (e.g. issue happens only occasionally):
- The issue happens all the time.
- These errors occur when port state change notification (form down to up) come for fabric ports from syncd. Since orchagent in linecard only knows about the front panel ports and recycle port (as supplied in port_config.ini and confirmed by configuration), orchagent does not have corresponding port oids for the received fabric ports. Hence these errors are displayed. We need to either mask these error messages coming for the fabric ports or linecard orchagent should retrieve fabric port oids from SAI and match them with port oids given via port state notifications to avoid these error messages.