Notifications
You must be signed in to change notification settings - Fork 1.3k
[chassis] Add HLD for fabric port handling in chassis #668
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
Merged
Changes from 4 commits
Commits
Show all changes
11 commits
Select commit
Hold shift + click to select a range
2e1f699
[chassis] Add HLD for fabric port handling in chassis
Arista-Jenkins fd06e67
[chassis] Update fabric HLD with hotswap handling and some future work
Arista-Jenkins 72f68a9
minor typo
Arista-Jenkins 4bd45e1
Merge remote-tracking branch 'upstread/master'
Arista-Jenkins ed4b8d5
Merge remote-tracking branch 'upstream/master'
Arista-Jenkins ac9c041
Move fabric.md to voq directory and update the contents to include mo…
Arista-Jenkins 4d68c7d
Merge remote-tracking branch 'upstream/master'
Arista-Jenkins 53fb2ff
Minor edit to add a note about container starts for fabric ASICs
Arista-Jenkins 6ca7362
Merge remote-tracking branch 'upstream/master'
Arista-Jenkins dc021dc
Add Everflow for VOQ chassis HLD v1
Arista-Jenkins 30b27dc
Remove incorrect merge
Arista-Jenkins File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,163 @@ | ||
| # Fabric port support on Sonic | ||
|
|
||
| # High Level Design Document | ||
| #### Rev 1 | ||
|
|
||
| # Table of Contents | ||
| * [List of Tables](#list-of-tables) | ||
| * [List of Figures](#list-of-figures) | ||
| * [Revision](#revision) | ||
| * [About this Manual](#about-this-manual) | ||
| * [Scope](#scope) | ||
| * [Definitions/Abbreviations](#definitionsabbreviations) | ||
| * [1 Requirements](#1-requirements) | ||
| * [2 Design](#2-design) | ||
| * [3 Testing](#3-testing) | ||
| * [4 Future Work](#4-future-work) | ||
|
|
||
| # List of Tables | ||
| * [Table 1: Abbreviations](#definitionsabbreviations) | ||
|
|
||
| # List of Figures | ||
|
|
||
| # Revision | ||
| | Rev | Date | Author | Change Description | | ||
| |:---:|:-----------:|:------------------:|--------------------| | ||
| | 1 | Aug-28 2020 | Ngoc Do, Eswaran Baskaran (Arista Networks) | Initial Version | | ||
| | 1.1 | Sep-1 2020 | Ngoc Do, Eswaran Baskaran (Arista Networks) | Add hotswap handling | | ||
|
|
||
| # About this Manual | ||
|
|
||
| This document provides an overview of the SONiC support for fabric ports that are present in a VOQ-based chassis. These fabric ports are used to interconnect the forwarding Network Processing Units within the VOQ chassis. | ||
|
|
||
| # Scope | ||
|
|
||
| This document covers: | ||
|
|
||
| - Bring up of fabric ports in a VOQ chassis. | ||
| - Monitoring the fabric ports in forwarding and fabric chips. | ||
|
|
||
| This document builds on top of the VOQ chassis architecture discussed [here](https://github.com/Azure/SONiC/blob/90c1289eaf89a70939e7c81e042e261947c6a850/doc/chassis/architecture.md) and the multi-ASIC architecture discussed [here](https://github.com/Azure/SONiC/blob/2f320430c8199132c686c06b5431ab93a86fb98f/doc/multi_asic/SONiC_multi_asic_hld.md). | ||
|
|
||
| # Definitions/Abbreviations | ||
|
|
||
| | | | | | ||
| |------|--------------------|--------------------------------| | ||
| | SSI | Supervisor SONiC Instance | SONiC OS instance on a central supervisor module that controls a cluster of forwarding instances and the interconnection fabric. | | ||
| | NPU | Network Processing Unit | Refers to the forwarding engine on a device that is responsible for packet forwarding. | | ||
| | ASIC | Application Specific Integrated Circuit | In addition to NPUs, also includes fabric chips that could forward packets or cells. | | ||
| | cell | Fabric Data Units | The data units that traverse a cell-based chassis fabric. | | ||
|
|
||
| # 1 Requirements | ||
|
|
||
| Fabric ports are used in systems in which there are multiple forwarding ASICs are required to be connected. Traffic passes from one front panel port in a forwarding ASIC over a fabric network to one or multiple front panel ports on one or other ASICs. The fabric network is formed using fabric ASICs. Fabric links on the fabric network connect fabric ports on forwarding ASICs to fabric ports on fabric ASICs. | ||
|
|
||
| High level requirements: | ||
|
|
||
| - SONiC needs to form a fabric network among forwarding ASICs, monitor and manage it. Monitoring could include link statistics, error monitoring and reporting, etc. | ||
| - SONiC should be able to initialize fabric asics and manage them similar to how forwarding ASICs are managed - using syncd and sairedis calls. | ||
|
|
||
| # 2 Design | ||
|
|
||
| ## 2.1 Fabric ASICs | ||
|
|
||
| Fabric asics are used to form a fabric network for connecting forwarding ASICs. For each fabric port on a forwarding ASIC, there is a fabric link in the fabric network connecting to a fabric port on a fabric asic. There are typically multiple fabric links between a pair of (NPU, fabric asic) to balance traffic. We use the same approach to initializing and managing fabric asics as we are doing today for forwarding ASICs. A typical chassis implementation will be to manage all the fabric ASICs in a chassis from the control card or the Supervior Sonic Instance (SSI). We will leverage the work done in the multi-ASIC HLD and instantiate groups of containers for the fabric ASICs. | ||
|
|
||
| For each fabric ASIC, there will be: | ||
|
|
||
| - Database container | ||
| - Swss container | ||
| - Syncd container | ||
|
|
||
| Unlike forwarding ASICs, fabric ASICs do not have any front panel ports, but only fabric ports. So all the front panel port related containers like lldp can be disabled for fabric ASICs. | ||
|
|
||
eswaranb marked this conversation as resolved.
Show resolved
Hide resolved
|
||
| ## 2.2 Database Schemas | ||
|
|
||
| ``` | ||
| DEVICE_METADATA: { | ||
| "switch_type": “fabric” | ||
| "switch_id": {{switch_id}} | ||
| } | ||
| ``` | ||
|
|
||
| The switch_id needs to be assigned to be unique for each fabric ASIC. The SAI VOQ specification recommends that this number be assigned to be different than the switch_id assigned to the forwarding ASICs in the chassis. | ||
|
|
||
| Fabric port statistics will be stored in table FABRIC_PORT_TABLE in STATE_DB. Typically, the statistics about a fabric port includes: | ||
|
|
||
| - Status: Up or down. | ||
| - Remote peer: Peer name, fabric port. | ||
| - Link errors: CRC errors. | ||
| - Counters: RX cells, TX cells, FEC (corrected, uncorrected). | ||
|
|
||
| Fabric port statistics will be updated periodically, say, for every 10s. | ||
|
|
||
| ``` | ||
| STATE_DB:FABRIC_PORT_TABLE:{{fabric_port_name}} | ||
| "lane": {{number}} | ||
| "status": “up”|”down” | ||
| "remote_switch_id": {{number}} | ||
| "remote_lane": {{number}} | ||
| “rx_cells”: {{number}} | ||
| “tx_cells”: {{number}} | ||
| "crc_errors": {{number}} | ||
| “fec_errors”: {{number}} | ||
| “fec_errors_corrected”: {{number}} | ||
| ``` | ||
eswaranb marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
|
||
| Note that the FABRIC_PORT_TABLE will also have entries in the Linecard Sonic instances because there are fabric ports in each forwarding ASIC as well. | ||
|
|
||
| ## 2.3 System Initialization | ||
|
|
||
| As part of multi-ASIC support, /etc/sonic/generated_services.conf contains the list of services which will be created for each asic when the system boots up. This is read by systemd-sonic-generator to generate the service files for each container that needs to run. | ||
|
|
||
| Since the fabric ASIC doesn’t need lldp, bgpd and teamd containers to run, systemd-sonic-generator will be modified to not start these services for the fabric ASICs. | ||
|
|
||
| ## 2.4 Fabric Card Hotswap | ||
|
|
||
| PMON will be responsible for detecting card presence and hotswap events using the get_change_event API. A new systemd service will be responsbile for turning on/off the service files for the syncd, database and swss containers that manage each fabric ASIC. When the fabric card is removed, the containers that manage the fabric ASICs that are part of that fabric card will be stopped. These will be re-started when the fabric card is inserted later. | ||
|
|
||
| ## 2.5 Orchagent | ||
|
|
||
| Orchagent creates the switch using the SAI API similar to creating the switch for a forwarding ASIC, except that the switch type will be fabric. When the ASIC is initialized, all the fabric ports are initialized by default. The fabric ports are a subtype of SAI Port object and it can be obtained by getting all the fabric port objects from SAI. Since there are no front panel ports on a fabric ASIC, port_config.ini will be empty and portsyncd will not run. | ||
|
|
||
| On fabric ASICs, OrchDaemon will only monitor and manage fabric ports. It will not maintain cpu port and front panel port related ochres, such as PortsOrch, IntfsOrch, NeighborOrch, VnetOrch, QosOrch, TunnelOrch, and etc. To simplify the change, we will just create FabricOrchDaemon inheriting OrchDaemon for fabric ASICs and this will only run FabricPortsOrch, the module responsible for managing fabric ports. | ||
|
|
||
| ## 2.6 Fabric Ports in Forwarding ASICs | ||
|
|
||
| When a forwarding ASIC is initialized, the fabric ports are initialized by default by SAI. Orchagent will run FabricPortsOrch in addition to all the other orchs that needs to be run to manage the forwarding ASIC. Fabric port monitoring and handling is identical to what happens on a Fabric ASIC. | ||
|
|
||
| ## 2.7 Cli commands | ||
|
|
||
| ``` | ||
| > show fabric counters [asic_name] [port_id] | ||
eswaranb marked this conversation as resolved.
Outdated
Show resolved
Hide resolved
|
||
|
|
||
| asic2 fabric port counter (number of fabric ports: 192) | ||
|
|
||
| PORT RxCells TxCells Crc Fec Corrected | ||
| ------------------------------------------------------------------------- | ||
| 0 : 71660578 2 0 0 0 | ||
| 1 : 71659798 1 0 0 213 | ||
| 2 : 0 1 0 0 167 | ||
| 3 : 0 2 0 0 193 | ||
| ``` | ||
|
|
||
| ### 2.7.1 Fabric Status | ||
|
Contributor
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. As there can be many fabric links in the chassis, may be even more useful if there is a CLI to only display the links/fabric ports that have errors. Eg.. "show fabric counters errors" |
||
|
|
||
| In a later phase, a `show fabric status` command will be added to show the remote switch ID and link ID for each fabric link of an ASIC. This will be obtained from the SAI_PORT_ATTR_FABRIC_REACHABILITY port attribute of the fabric port. Note that for fabric links that do not have a link partner because of the configuration of the chassis, this will show the status as `down`. The status will also be `down` for fabric links that are down due to some other physical error. To identify links that are down due to error vs links that are not expected to be up because of the chassis connectivity, we need to build up a list of expected fabric connectivity for each ASIC. This can be computed ahead of time based on the vendor configuration and populated in the minigraph. This will be implemented in a later phase. | ||
|
|
||
| # 3 Testing | ||
|
|
||
| Fabric port testing will rely on sonic-mgmt tests that can run on chassis hardware. | ||
|
|
||
| - Test fabric port mapping: To verify the fabric mapping, we can inspect the remote switch ID that are saved in the STATE_DB and match that with the known chassis architecture. | ||
|
|
||
| - Test traffic and counters: Send traffic through the chassis and verify traffic going through fabric ports via counters. | ||
|
|
||
| # 4 Future Work | ||
|
|
||
| - In this proposal, all fabric ports on fabric ASICs or forwarding ASICs that join to form the fabric network will be enabled even when there are no peer ports available. We could provide a config model for the platforms to express the expected fabric connectivity and turn off unnecessary fabric ports. | ||
|
|
||
| - Fabric ports that do not have a peer port will show up as a ‘down’ port. Fabric ports that do have a peer port could also go ‘down’ and there is no current way to differentiate this from a fabric port that does not have a peer port. This can be detected if the config model can express the expected fabric connectivity. | ||
|
|
||
| - Monitor, detect and disable fabric ports that consistently show errors. | ||
|
|
||
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!