# DPU Restart – Solution for database out of sync
## Problem Statement
Comment thread
zjswhhh marked this conversation as resolved.
When DPU restarts (either as a planned or an unexpected event), DPU_[APPL|STATE] _DB that are hosted on NPU will not be restarted along with DPU. This causes some states to be out of sync and leads to unexpected behaviors in HA scenarios. Today's [SmartSwitch reboot HLD](https://github.com/sonic-net/SONiC/blob/master/doc/smart-switch/reboot/reboot-hld.md) does not cover database cleanup.

We observed a couple of issues with this problem:
1. BFD passive sessions (on DPUs) are created once only by hamgrd (when “DPU” table in NPU’s CONFIG_DB is consumed). When DPU is restarted, these BFD sessions are removed and will never be added again.
2. DPU_STATE_DB still holds stale entries/values for HA objects.
3. Even if we clean up DPU_[APPL|STATE] _DB, NPU’s APPL_DB and STATE_DB will still have stale “HA_SCOPE_CONFIG_TABLE” and “HA_SET_CONFIG_TABLE”.

## Solutions
The following are the proposed actions during DPU reboot.

1. Cleanup `DPU_*_DB` instances when DPU boots up.
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Cleanup happens when swss is restarted. It covers both DPU reboot and critical processes restart

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Done.

1. SDN controller needs to monitor NPU `STATE_DB` entries below:
1. `CHASSIS_MODULE_TABLE|DPU<dpu_index>: {'admin_status': 'up|down', 'oper_status': 'up|down'}`
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

should this be removed?

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This is still required to confirm DPU is ready to be configured.

This table entry will be updated by [SmartSwitch pmon](https://github.com/sonic-net/SONiC/blob/master/doc/smart-switch/pmon/smartswitch-pmon.md).
1. `DPU_RESET_INFO|DPU<dpu_index>: {'reset_status': 'true|false', 'last_reset_status_update': timestamp}`
This table will be updated by hamgrd based on `CHASSIS_STATE_DB|DPU_STATE`. Either `dpu_control_plane_state` or `dpu_midplane_link_state` being down will trigger hamgrd to set `reset_status` to `true`.
Controller will update the status to `false` when it finishes the service provision and HA programming after DPU is up.
1. `DPU_RESET_INFO|DPU<dpu_index>: {'dpu_ready': 'true|false', 'last_dpu_readiness_update': timestamp}`
This field indicates if dpu is ready to be provisioned. Hamgrd will set the value to `false` when `dpu_control_plane_state` or `dpu_midplane_link_state` goes down, and set the value back to `true` when the states are up.

1. SDN controller will then
1. Delete stale HA_SET_CONFIG and HA_SCOPE_CONFIG
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Please add the timing, when reset_status changes to true

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Included already in last bullet point.

1. Re-program DASH objects, HA_SET_CONFIG and HA_SCOPE_CONFIG
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

add condition when dpu_ready changes to true

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Included already in last bullet point.

1. Once services are provisioned, HA is programmed, SDN controller will set `reset_status` to `false`
1. Hamgrd needs to change the passive BFD session creation logic, today the sessions are created statically. We need this change to avoid hamgrd restart. Hamgrd needs to create BFD session if `dpu_control_plane_state` changes from down to up.
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

or dpu_midplane_state from down to up

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

checked Dylan's implementation, both state should be up?

Updated the working a bit to avoid confusion.


Note that DashHaOrch should cache the BFD session parameters, remove and create the sessions accordingly in planned shutdown.

## Workflow

```mermaid
sequenceDiagram
participant SDN Controller
participant hamgrd
participant pmon
participant NPU APPL_DB
participant NPU STATE_DB
participant NPU CHASSIS_STATE_DB
participant DPU_APPL_DB
participant DPU_STATE_DB
participant DPU

DPU->>DPU: 1. DPU shutdown
pmon->>NPU CHASSIS_STATE_DB: 2. Update dpu state to down
hamgrd->>NPU STATE_DB: 3. update local vdpu state in `DASH_HA_SCOPE_STATE` table, update `DPU_RESET_INFO`
NPU STATE_DB->>SDN Controller: 4. DPU_RESET_INFO|DPU0: {"reset_status": "true", "dpu_ready": "false"}
hamgrd->>DPU_APPL_DB: 5. hamgrd remove passive BFD sessions
SDN Controller->>hamgrd: 6. Delete HA_SCOPE_CONFIG and HA_SET_CONFIG
hamgrd->>DPU_APPL_DB: 7. Delete HA_SET, HA_SCOPE
hamgrd->>NPU STATE_DB: 8. Delete HA_SCOPE_STATE_TABLE, delete VNet routes.
DPU->>DPU: 9. DPU boots up
DPU->>DPU_APPL_DB: 10. Cleanup Database
DPU->>DPU_STATE_DB: 11. Cleanup Database
pmon->>NPU CHASSIS_STATE_DB: 12. Update DPU state to Up
hamgrd->>DPU_APPL_DB: 13. Create BFD passive sessions.
hamgrd->>NPU STATE_DB: 14. DPU_RESET_INFO|DPU0: {"dpu_ready": "true"}

NPU STATE_DB->>SDN Controller: 15. DPU_RESET_INFO|DPU0: {"dpu_ready": "true"} && CHASSIS_MODULE_TABLE|DPU0 {'admin_status':'up'} &&CHASSIS_MODULE_TABLE|DPU0 {'oper_status':'up'}
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Did you see SDN controller should not access CHASSIS_MODULE_TABLE?

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

SDN controller will not use CHASSIS_STATE_DB. CHASSIS_MODULE_TABLE is in NPU's STATE_DB.



SDN Controller->>hamgrd: 16. Create DASH objects, HA_SCOPE_CONFIG and HA_SET_CONFIG
SDN Controller->>NPU STATE_DB: 17. DPU_RESET_INFO|DPU0: {"reset_status": "false"}
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

If DPU crashed before reaching step 17, hamgrd will sets reset_status to true, which is already true but timestamp will be new. Controller needs to restart the reset process (delete ha scope/ha set). I still think we should converge on dpu_ready so controller only needs to watch this field. If it is false, start the reset process by removing ha config. When it is true, adding ha config etc.

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Yes, step 17 is actually to write the DB entry. Updated for clarity.

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I think we need to specifically call out to controller that it is possible dpu crashes again before controller sets reset_status to false. So it needs to keep track of status last update time to detect this situation. Otherwise, DPU will be stuck in the bad state.

```