Hello,

I would like to report an issue with the Modelica.Media.Air.ReferenceMoistAir media.

From unexpected simulation results, I implemented the following simple model (cf. enclosed model): a constant mass flow source (Modelica.Fluid.Sources.MassFlowSource_T) with X = {0, 1} connected to a constant volume tank (Modelica.Fluid.Vessels.ClosedVolume) with X = {0.5, 0.5} @ t = 0. The tank water mass is expected to remain the same and the total mass was expected to increase linearly. Instead, the tank water mass increased and the total fluid mass increasing beyond expectation and beyond the water mass increase.

XBalance.zip

The issue has been observed with Dymola 2020 using Modelica Standard Library - Version 3.2.3 and confirmed using Modelica Standard Library - Version 4.0.0. As a comparison, using Modelica.Media.IdealGases.MixtureGases.AirSteam, the observed error is more likely due to computing small error propagation.

Quick investigations pointed to ReferenceMoistAir density and derivated functions.

Please let me know if problem if the problem has already been reported and if solution has been developed.