Read noise errors sometimes triggered due to CTE #425

@djschlegel

Description

@djschlegel

The CTE problem can trigger read noise errors in NightWatch. Recent examples from the night 07-23-2024 had two backup tiles that triggered this error on the z1-D amplifiers (exposures 245014, 245021). I suspect the read noise is computed in the overscan region, and is thrown off by the CTE when there is a bright object in fibers near the overscan. (Is this interpretation correct?)

Options?

(1) Do nothing except in documentation. This is triggering off a real problem (CTE), even if the error is not obvious. This could be added to the NightWatch documentation. (One other comment is that most of the documentation is on the "Troubleshooting" page linked off NightWatch, rather than the "Documentation" page.)

(2) Run the CTE correction code within NightWatch to correct for the CTE before measuring the read noise.

(3) Explicitly trigger on the CTE.