2 changes: 2 additions & 0 deletions src/EnergyPlus/ChillerElectricEIR.cc
Original file line number Diff line number Diff line change
Expand Up @@ -1962,6 +1962,8 @@ void ElectricEIRChillerSpecs::calculate(EnergyPlusData &state, Real64 &MyLoad, b
state, this->CWPlantLoc, this->CondMassFlowIndex, this->CDPlantLoc, DataPlant::CriteriaType::MassFlowRate, this->CondMassFlowRate);

if (this->CondMassFlowRate < DataBranchAirLoopPlant::MassFlowTolerance) {
// Shut chiller off if there is no condenser water flow
MyLoad = 0.0;
Copy link
Collaborator

@rraustad rraustad Oct 19, 2024

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This does look like it boils down to this. I looked at PullCompInterconnectTrigger to see what that was trying to accomplish. This code looks like it can be deleted. I'm not asking for that to happen here but it's extra clock cycles. Removed in #10794,

    // Check to make sure we didn't reuse the index in multiple components
    if (CurCriteria.CallingCompLoopNum != plantLoc.loopNum || CurCriteria.CallingCompLoopSideNum != plantLoc.loopSideNum ||
        CurCriteria.CallingCompBranchNum != plantLoc.branchNum || CurCriteria.CallingCompCompNum != plantLoc.compNum) {
        // Diagnostic fatal: component does not properly utilize unique indexing
    }

if (this->EvapMassFlowRate < DataBranchAirLoopPlant::MassFlowTolerance) {
// Use PlantUtilities::SetComponentFlowRate to decide actual flow
PlantUtilities::SetComponentFlowRate(
Expand Down