Skip to content

Report System Summary:Thermostat Schedules depends on order of ZoneControl:Thermostat control types #10857

@JasonGlazer

Description

@JasonGlazer

Issue overview

The Thermostat Schedules table which appears under the System Summary tabular report changes depending on the order of control types shown in ZoneControl:Thermostat even though the list is "not order dependent."

To reproduce choose an example file that has ZoneControl:Thermostats with multiple control types such as 5ZoneAirCooled_VAVBoxMinAirFlowTurnDown.idf

Change the order of control types:

  ZoneControl:Thermostat,
    SPACE2-1 Control,        !- Name
    SPACE2-1,                !- Zone or ZoneList Name
    Zone Control Type Sched, !- Control Type Schedule Name
    ThermostatSetpoint:SingleCooling,  !- Control 1 Object Type
    CoolingSetPoint,         !- Control 1 Name
    ThermostatSetpoint:SingleHeating,  !- Control 2 Object Type
    HeatingSetpoint,         !- Control 2 Name
    ThermostatSetpoint:DualSetpoint,  !- Control 3 Object Type
    DualSetPoint;            !- Control 3 Name


to

  ZoneControl:Thermostat,
    SPACE2-1 Control,        !- Name
    SPACE2-1,                !- Zone or ZoneList Name
    Zone Control Type Sched, !- Control Type Schedule Name
    ThermostatSetpoint:DualSetpoint,  !- Control 3 Object Type
    DualSetPoint,            !- Control 3 Name
    ThermostatSetpoint:SingleCooling,  !- Control 1 Object Type
    CoolingSetPoint,         !- Control 1 Name
    ThermostatSetpoint:SingleHeating,  !- Control 2 Object Type
    HeatingSetpoint;         !- Control 2 Name

The Thermostat Schedules table changes from:

image

to:

image

Details

Some additional details for this issue (if relevant):

  • Tested on Windows 10
  • EnergyPlus 24.2

Checklist

Add to this list or remove from it as applicable. This is a simple templated set of guidelines.

  • Defect file added (list location of defect file here)
  • Ticket added to EnergyPlus Defect Complexity (Github Project)
  • Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)

Metadata

Metadata

Assignees

Labels

DefectIncludes code to repair a defect in EnergyPlus

Type

No type

Projects

No projects

Milestone

No milestone

Relationships

None yet

Development

No branches or pull requests

Issue actions