Coil:Cooling:DX cannot mimic Coil:Cooling:DX:MultiSpeed PLF > 1 behavior #11164

@shorowit

Description

@shorowit

Issue overview

I am comparing two models that are identical except one uses Coil:Cooling:DX:MultiSpeed and one uses Coil:Cooling:DX. The results are perfectly identical for many hours, but they diverge whenever the load exceeds the capacity (RTF=1). During those timesteps, they agree on the load, but the Coil:Cooling:DX shows higher electricity use than the Coil:Cooling:DX:MultiSpeed model. I interpret this to mean that the energy reported by the Coil:Cooling:DX is actually using a RTF > 1 instead of limiting it to 1.

Example output:
Image

Top graph is Cooling Coil Runtime Fraction. Bottom graph is Cooling Coil Electricity Energy (J). The bottom graph shows that the models agree when RTF < 1 but diverge when RTF=1.

Operating System (Multiple choices)

Ubuntu

Operating System Version

24.04

Version of EnergyPlus

25.1

Unmethours link or helpdesk ticket number

N/A

Defect file

2 IDFs and EPW:
coildx.zip

Metadata

Metadata

Assignees

Labels

TriageIssue needs to be assessed and labeled, further information on reported might be neededUnconfirmedDefectDefect has not yet confirmed to be an actual issue