Notifications
You must be signed in to change notification settings - Fork 19.7k
Description
Did you test the latest bugfix-2.0.x code?
Yes, and the problem still exists.
Bug Description
Old version of Marlin 2.9.3 with dyze high temp thermistor,temp table 66 is working,temperature is detected on the hotend . Updated today to bug fix 2.0 exactly the same marlin config as 2.9.3 version but no readings from hotend thermistor at all.. Displays 0C/0C. Only after reversing to old firmware i get readings from thermistor. To be clear as this is a hi-temp thermistor TD500 the room temperature values are not stable ,this was always issue with 32bit boards and this thermistore. Hoewer thermistor is mostly stable with higher temperatures.
Bug Timeline
New issue,started after updating to bug fix 2.0
Expected behavior
Expected that firmware displays normal temperature readings from hotend
Actual behavior
After update to bugfix2.0 no reading from hotend. Room temp reading show 0C if I try to preheat hotend reading is 0C and after that thermal safety is triggered and printer is halted.
Downgrading firmware to 2.9.3 resolve this issue.
Steps to Reproduce
Update to Marlin bugfix 2.0X CONFIGURATION_ADV_H_VERSION 02010000
Use temp sensor table number 66 for DT500 dyze sensor
Compile the firmware and upload.
Reboot and check temp readings on hotend.
Observed reading is 0C on room temp value and 0C on hotend with preheating turned on
After this thermal runaway safety is triggered
Disabled futures
Junction Deviation,Linear advance,Arc future,Square wave stepping,Hybrid threshold.
Enabled futures:
Stelthchop,S curve,Classic jerk,Power loss recovery,Host command,Cancel object,PSU control,TMC debbug,Pins debbug.
Version of Marlin Firmware
Latest bugfix 2.0X
Printer model
Ender 3 pro
Electronics
SKR mini E3 2.0 STM32 2209
Add-ons
Removed all hardware add-ons for testing PSU switch,UPS
Bed Leveling
ABL Bilinear mesh
Your Slicer
Cura
Host Software
Pronterface
Additional information & file uploads
Issue is within the bugfix 2.0 code. Downgrading to 2.9.3 non bugfix version of marlin resolve this problem. All config settings within firmwares 2.9.3 and bugfix are the same but update outcome is diffrend as bugfix displays no readings at all on hotend.
Config files.zip