Re-add 127.0.0.1/8 when bringing down the interfaces
With sonic-net#5353, 127.0.0.1/16 was added to the lo interface, and then 127.0.0.1/8 was removed. However, when bringing down the lo interface, like during a config reload, 127.0.0.1/16 gets removed, but 127.0.0.1/8 isn't added back to the interface. This means that there's a period of time where 127.0.0.1 is not available at all, and services that need to connect to 127.0.01 (such as for redis DB) will fail. To fix this, when going down, add 127.0.0.1/8. Add this address before the existing configuration gets removed, so that 127.0.0.1 is available at all times. Note that running `ifdown lo` doesn't actually bring down the loopback interface; the interface always stays "physically" up. Signed-off-by: Saikrishna Arcot <[email protected]>
1 parent 602b945 commit 5566a58

1 file changed

Lines changed: 1 addition & 0 deletions

File tree

files/image_config/interfaces/interfaces.j2

Lines changed: 1 addition & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -26,6 +26,7 @@ iface lo inet loopback
2626
netmask 255.255.0.0
2727
scope host
2828
post-up ip addr del 127.0.0.1/8 dev lo
29+
down ip addr add 127.0.0.1/8 dev lo
2930
{% endblock loopback %}
3031
{% block mgmt_interface %}
3132