SOVTree doesn't find solutions for some parametrisations with extremely long membrane time-scales, which causes the fit to give errors.
Solution:
Revert to more basic membrane time-scale matching in these cases, i.e. wrap line 828 in compartmentfitter.py in a try-except block.